Hattersley Fig 1000 M PN20 Metering Station - Medium Flow - DN15
Typical lead time is 3 to 5 working days. We'll contact you if this changes.
Description
Fig. 1000M DZR Brass Medium Flow Metering Stations
Features & Benefits
• Precise and accurate measurement, conforming to BS 7350:1990
• Dezincification resistant material preventing corrosion cracking and fungal growth
• WRAS Approved for use with potable water up to 85°C
• Supplied with red and blue test points for upstream and downstream port identification
• Flow measurement accuracy of ±5%
• Available in size DN15 (1/2")
Pressure/Temperature Rating
• Threaded Ends
• PN25 Series B
• 15 bar at 120ºC
• 25 bar from -10 to 120ºC
Test Pressures
• Shell: 30 bar
Specification
• Conforms to BS 7350:1990
• WRAS Approved Product to 85°C
• Supplied fitted with two Figure 631 test points
• Outlet connection taper threaded BS EN 10266 (ISO 7-1) formerly BS 21
• Inlet connection screwed BS 2779 (ISO 228) parallel
• Suitable for use with flow rates down to 0.01l/s
Datasheet
Hattersley Fig 1000 M PN20 Metering Station - Medium Flow Datasheet